Implant Bone Interface
Editat de John Olderen Limba Engleză Paperback – 8 dec 2011
Preț: 351.82 lei
Preț vechi: 370.34 lei
-5% Nou
Puncte Express: 528
Preț estimativ în valută:
67.33€ • 69.94$ • 55.93£
67.33€ • 69.94$ • 55.93£
Carte tipărită la comandă
Livrare economică 29 ianuarie-04 februarie 25
Preluare comenzi: 021 569.72.76
Specificații
ISBN-13: 9781447118138
ISBN-10: 1447118138
Pagini: 208
Ilustrații: XXII, 177 p. 68 illus.
Dimensiuni: 193 x 270 x 11 mm
Ediția:Softcover reprint of the original 1st ed. 1990
Editura: SPRINGER LONDON
Colecția Springer
Locul publicării:London, United Kingdom
ISBN-10: 1447118138
Pagini: 208
Ilustrații: XXII, 177 p. 68 illus.
Dimensiuni: 193 x 270 x 11 mm
Ediția:Softcover reprint of the original 1st ed. 1990
Editura: SPRINGER LONDON
Colecția Springer
Locul publicării:London, United Kingdom
Public țintă
ResearchCuprins
I Histology of the Junctional Tissues.- 1 An Overview of the Histology of the Principal Interface Types in Orthopaedic Surgery Today.- 2 Biological Factors of Importance for Bone Integration of Implanted Devices.- 3 The Reaction of Bone to Bone Cement in Animals and Humans.- 4 New Observations on the Bone Cement—Bone Interface.- 5 Morphology of Implant—Bone Interface in Cemented and Non-cemented Endoprostheses.- 6 Tissue Reactions to Metallic Biomaterials.- 7 Osseo-integration of Metallic Implants in Animals and Humans.- 8 Histology of the Failed Implant.- 9 The Effects of Wear Particles on Periprosthetic Tissues.- 10 Failure Modes of Artificial Joint Implants Due to Particulate Implant Material.- 11 Pathology of Cemented Low-Friction Arthroplasties in Autopsy Specimens.- II Bone Cement.- 12 Time-Dependent Properties of Polymethylmethacrylate Bone Cement.- 13 The Scientific Basis of Vacuum Application of Bone Cement.- 14 Intrafemoral Pressure in Total Hip Replacement.- III Bone.- 15 Bone: The Architecture of Bone and How it is Influenced by External Loading.- IV Miscellaneous.- 16 Endosteal Lysis.- 17 Micro-motion: Consequences of Material Choices, Implant Design and Fit.- 18 Differential Movement Between Implant and Bone.- 19 A Preliminary Report on the Stem-Cement Interface and its Influence on the Bone-Cement Interface.- 20 Calcar/Collar Contact in Cemented Total Hip Arthroplasty.- 21 Trial of Cementless Versus Cemented Total Hip Arthroplasty: Preliminary Results.- 22 Intramedullary Cement Fixation: A Comparison of the Fixation of Custom-Made Prostheses with the Fixation of Standard Joint Replacements.- 23 Hydroxyapatite Crystals in Bone Ingrowth and Comparison of Autografts and Allographs: Preliminary Report.- 24 Fluoroscopically Controlled Radiographs inExamination of the Bone-Implant Interface: Preliminary Results.- 25 Conclusion.