Protective Relay Principles
Autor Anthony M. Slevaen Limba Engleză Hardback – 23 feb 2009
In the ever-evolving field of protective relay technology, an engineer’s personal preference and professional judgment are as important to power system protection as the physical relays used to detect and isolate abnormal conditions.
Invaluable Insights from an Experienced Expert
Protective Relay Principles focuses on probable power system failure modes and the important characteristics of the protective relays used to detect these postulated failures. The book presents useful new concepts in a way that is easier to understand because they are equally relevant to older, electromechanical and solid-state relays, and newer, more versatile microprocessor-based relays. It introduces the applications, considerations, and setting philosophies used in transmission-line, distribution-line, and substation applications, covering concepts associated with general system operations and fault detection. Topics include relay load limits, cold load pickup, voltage recovery, and arc flash. The author also delves into the philosophies that engineers employ in both urban and rural areas, with a detailed consideration of setpoint function.
Analysis of Key Concepts That Are Usually Just Glossed Over
This versatile text is ideal for new engineers to use as a tutorial before they open the instruction manuals that accompany multi-function microprocessor-based relays. Guiding readers through the transient loading conditions that can result in relay misoperation, the author elaborates on concepts that are not generally discussed, but can be very helpful in specific applications. Readers will come away with an excellent grasp of important design considerations for working with overcurrent, over- and undervoltage, impedance, distance, and differential type relay functions, either individually or in combination. Also useful for students as a textbook, this book includes practical examples for many applications, and offers guidance for more unusual ones.
Preț: 1313.14 lei
Preț vechi: 1601.40 lei
-18% Nou
Puncte Express: 1970
Preț estimativ în valută:
251.38€ • 258.53$ • 208.55£
251.38€ • 258.53$ • 208.55£
Carte tipărită la comandă
Livrare economică 20 februarie-06 martie
Preluare comenzi: 021 569.72.76
Specificații
ISBN-13: 9780824753726
ISBN-10: 0824753720
Pagini: 368
Ilustrații: 195 b/w images, 34 tables and 387 equations
Dimensiuni: 156 x 234 x 23 mm
Greutate: 0.7 kg
Ediția:Special.
Editura: CRC Press
Colecția CRC Press
ISBN-10: 0824753720
Pagini: 368
Ilustrații: 195 b/w images, 34 tables and 387 equations
Dimensiuni: 156 x 234 x 23 mm
Greutate: 0.7 kg
Ediția:Special.
Editura: CRC Press
Colecția CRC Press
Public țintă
Academic, Professional, and Professional Practice & DevelopmentCuprins
Power System Components. Power System Sub-Components. Abnormal Power System Conditions. Short Circuit Calculations. Protective Relay Functions. Protective Relay Functional Combinations. Zones and Regions of Protection. Physical Characteristics of Protective Relays. Setting Considerations. Protection and Control Schemes. Protective Relay Coordination. Distribution Line Protection Radial Lines. Distribution Line Protection Network Lines. Transmission Line Protection. Transformer Protection. Bus Protection. Breaker Failure Relaying. Capacitor Protection. Shunt and Series Reactor Protection. Grid Protection.
Notă biografică
Anthony Sleva is president of Sleva Associates, an electrical consulting and training company. He is a registered Professional Engineer with a BSEE degree from Pennsylvania State University. During his career, he has designed electrical systems for nuclear generating stations; designed 500-230 KV, 230-69 KV, 138-12 KV and 69-12 KV substations; provided technical support to power dispatchers, system operators and plant operators; and developed technical training programs for technicians, drafters, designers and technical clerks. Mr. Sleva specializes in the analysis of power system events that cause the loss of customer load and/or the initiation of emergency load control procedures as well as events that may have been caused by incorrect protective relay actuations.
Descriere
This bestselling book provides an understanding of various power system components and their failure modes as well as the various types of protective relays used to detect and isolate abnormal power system conditions. The author shows readers how to recognize conditions and system configurations where power system protection can be optimized. He also discusses applications and control schemes used to ensure proper protective relay actuation and considers set points for protective relays intended to detect short circuits on distribution lines, transmission lines, transformers, and buses. Additionally, the text examines several schemes used to detect that a circuit breaker has failed to interrupt the flow of a fault current.