Quantitative videoangiocardiography

Autor R.P. van Wijk van Brievingh
en Limba Engleză Paperback – 30 sep 1975
2. Vidicor 3. Anacor 4. Digicor 5. Magnetic Recording of the Videosignal VI. GEOMETRIC MODEL I. Introduction 2. Survey of Models 3. Preparation of Casts 4. Index of Irregularity 5. In Vitro Tests VII. DETECTION OF THE VENTRICULAR CONTOUR I. Introduction 2. Semi-automatic Methods 3. The Influence of the Trained Operator 4. Conclusions VIII. DATA CONVERSION 1. Introduction 2. Light-pen System and Contour Memory 3. Digicor 4. Evaluation Procedure 5. Data Presentation IX. SOFTWARE SYSTEM 1. Introduction 2. Modular Structure 3. Data Conversion 4. Volume Calculation 5. Data Presentation 6. Special Programs X. IN VIVO TESTS 1. Introduction 2. Materials and Methods 3. Results XI. UNCERTAINTY ANALYSIS I. Introduction 2. Uncertainty Intervals for Relevant Variables Propagation 3. of Uncertainty 4. Uncertainty Interval in the Result XII. DISCUSSION XIII. APPENDIX 1. Glossary 2. Dedvations 3. Results XIV. REFERENCES 1. Literature 2. Internal Reports ACKNOWLEDGEMENTS VIII Illustrations Figure Block-diagram of Instrumentation 12 1. 1 Central Synchronization 17 2. 1 2. 2 Effect of Scattered Radiation (Biplane) 18 Block-diagram of X-ray/TV-system 2. 3 21 2. 4 Test-object for OTF-measurement 25 Spatial Responses and Optical Transfer Functions 2. 5 26 Deviation from Isoplanasy and Influence of Additional Equipment 2. 6 28 2. 7 Temporal Modulation Transfer Function Curves 31 2. 8 Biplane Projections 33 2. 9 X-ray Aiming Device 36 2. 10 Calibration Curve 37 3. 1 Concentration vs. Tube Voltage Curves 45 3. 2 Markers and Applicators 48 3. 3.
Citește tot Restrânge

Preț: 36397 lei

Preț vechi: 38312 lei
-5% Nou

Puncte Express: 546

Preț estimativ în valută:
6965 7245$ 5750£

Carte tipărită la comandă

Livrare economică 14-28 aprilie

Preluare comenzi: 021 569.72.76

Specificații

ISBN-13: 9789029817004
ISBN-10: 9029817003
Pagini: 220
Ilustrații: XV, 203 p.
Dimensiuni: 152 x 229 x 12 mm
Greutate: 0.3 kg
Ediția:1975
Editura: SPRINGER NETHERLANDS
Colecția Springer
Locul publicării:Dordrecht, Netherlands

Public țintă

Research

Cuprins

I. Introduction.- 1. Medical Background.- 2. Review of Possible Methods.- 3. Aspects of the Method Chosen.- 4. Set-up of the Measurement System.- II. The X-Ray Installation as a Part of the Measurement System.- 1. Introduction.- 2. Central Synchronization of the X-ray-television System.- 3. Imaging Characteristics of the Image Intensifier-television System.- 4. Geometry in the Biplane Installation.- 5. Calibration.- III. Fractionized Contrast Medium Injection.- 1. Introduction.- 2. Calculation of the Number of Fractions.- 3. Experimental Determination of the Concentration of Medium.- 4. Time Programming.- 5. Radiation Dose.- IV. Subtraction as an Assistant Tool.- 1. Introduction.- 2. Conversion of the Videosignal.- 3. Procedure.- 4. Example.- V. Integrated Information Recording.- 1. Introduction.- 2. Vidicor.- 3. Anacor.- 4. Digicor.- 5. Magnetic Recording of the Videosignal.- VI. Geometric Model.- 1. Introduction.- 2. Survey of Models.- 3. Preparation of Casts.- 4. Index of Irregularity.- 5. In Vitro Tests.- VII. Detection of the Ventricular Contour.- 1. Introduction.- 2. Semi-automatic Methods.- 3. The Influence of the Trained Operator.- 4. Conclusions.- VIII. Data Conversion.- 1. Introduction.- 2. Light-pen System and Contour Memory.- 3. Digicor.- 4. Evaluation Procedure.- 5. Data Presentation.- IX. Software System.- 1. Introduction.- 2. Modular Structure.- 3. Data Conversion.- 4. Volume Calculation.- 5. Data Presentation.- 6. Special Programs.- X. In Vivo Tests.- 1. Introduction.- 2. Materials and Methods.- 3. Results.- XI. Uncertainty Analysis.- 1. Introduction.- 2. Uncertainty Intervals for Relevant Variables.- 3. Propagation of Uncertainty.- 4. Uncertainty Interval in the Result.- XII. Discussion.- XIII. Appendix.- 1. Glossary.- 2. Derivations.- 3. Results.- XIV.References.- 1. Literature.- 2. Internal Reports.- Acknowledgements.