Residual Current Devices: Selection, Operation, and Testing
Autor Stanislaw Czappen Limba Engleză Paperback – 19 ian 2022
- Explains the practical aspects of the selection and utilization of residual current devices
- Provides guidance on the operation of residual current devices in modern circuits characterized by nonsinusoidal earth fault currents
- Features remedies for challenges in unwanted tripping of residual current devices during the obligatory verification of low-voltage systems
Preț: 735.22 lei
Preț vechi: 966.44 lei
-24% Nou
Puncte Express: 1103
Preț estimativ în valută:
140.71€ • 146.16$ • 116.88£
140.71€ • 146.16$ • 116.88£
Carte tipărită la comandă
Livrare economică 27 ianuarie-10 februarie 25
Preluare comenzi: 021 569.72.76
Specificații
ISBN-13: 9780323897839
ISBN-10: 0323897835
Pagini: 250
Ilustrații: 80 illustrations (30 in full color)
Dimensiuni: 152 x 229 x 22 mm
Greutate: 0.34 kg
Editura: ELSEVIER SCIENCE
ISBN-10: 0323897835
Pagini: 250
Ilustrații: 80 illustrations (30 in full color)
Dimensiuni: 152 x 229 x 22 mm
Greutate: 0.34 kg
Editura: ELSEVIER SCIENCE
Cuprins
1. Genesis of residual current devices
2. Construction of modern residual current devices
3. Types, parameters, and reliability of residual current devices
4. Protection against electric shock
5. Protection against fire
6. Requirements of standards with reference to application of residual current devices
7. Backup protection of residual current devices
8. Circuits with nonsinusoidal currents
9. Earth fault loop impedance measurement in circuits with residual current devices
10. Residual current devices in circuits with surge protective devices
11. Immunity of residual current devices to the impulse leakage currents
12. Verification of residual current devices
Summary
Appendix A Examples of RCD selection
Appendix B Standards regarding residual current devices’ performance, application, and operation
2. Construction of modern residual current devices
3. Types, parameters, and reliability of residual current devices
4. Protection against electric shock
5. Protection against fire
6. Requirements of standards with reference to application of residual current devices
7. Backup protection of residual current devices
8. Circuits with nonsinusoidal currents
9. Earth fault loop impedance measurement in circuits with residual current devices
10. Residual current devices in circuits with surge protective devices
11. Immunity of residual current devices to the impulse leakage currents
12. Verification of residual current devices
Summary
Appendix A Examples of RCD selection
Appendix B Standards regarding residual current devices’ performance, application, and operation
Recenzii
"This book would be of most interest to our readers who want to learn abot the operations and details of RCDs. It contains very good technical details and good discussions relating to applicable standardrs. Note that this book is exclusively focused on RCDs and does not cover GFCIs. Although the operating principals between RCDs and GFCIs are the same, the threshold requiremenets differ between international standards and US standards. Nonetheless, this is a very useful book for learning about these very important electrical safety devices." --IEEE - Electrical Insulation Magazine