Collimator-Based Tracking with an Add-On Multileaf Collimator: Modification of a commercial collimator system for realtime applications: BestMedDiss
Autor Andreas Böhleren Limba Engleză Paperback – 9 oct 2015
Verification was performed by measuring the latency of the system as well as the impact on applied dose to a predefined target volume, moving in the leaf's travel direction. Latency measurements in software were accomplished by comparing the target and current positions of the leaves. For dose measurements, a Gafchromic EBT2 film was placed beneath the target 4D phantom, in between solid water plates, and moved alongside with it.
Based on the results, a tracking-capable add-on collimator seems to be a useful tool for reducing the margins for the treatment of small, slow-moving targets.
Radiotherapy is one of the most important methods used for the treatment of cancer. Irradiating a moving target is also one of the most challenging tasks to accomplish in modern radiotherapy.
Preț: 338.24 lei
Preț vechi: 356.03 lei
-5% Nou
Puncte Express: 507
Preț estimativ în valută:
64.74€ • 69.61$ • 53.97£
64.74€ • 69.61$ • 53.97£
Carte tipărită la comandă
Livrare economică 20 decembrie 24 - 03 ianuarie 25
Preluare comenzi: 021 569.72.76
Specificații
ISBN-13: 9783658106577
ISBN-10: 3658106573
Pagini: 68
Ilustrații: XIV, 53 p. 18 illus., 14 illus. in color.
Dimensiuni: 148 x 210 x 10 mm
Greutate: 0.1 kg
Ediția:1st ed. 2016
Editura: Springer Fachmedien Wiesbaden
Colecția Springer
Seria BestMedDiss
Locul publicării:Wiesbaden, Germany
ISBN-10: 3658106573
Pagini: 68
Ilustrații: XIV, 53 p. 18 illus., 14 illus. in color.
Dimensiuni: 148 x 210 x 10 mm
Greutate: 0.1 kg
Ediția:1st ed. 2016
Editura: Springer Fachmedien Wiesbaden
Colecția Springer
Seria BestMedDiss
Locul publicării:Wiesbaden, Germany
Public țintă
ResearchCuprins
1 Introduction.- 2 Literature Overview.- 3 Hypothesis & Goals.- 4 Materials & Methods.- 5 Results.- 6 Discussion.- 7 Conclusions.
Notă biografică
After his graduation in 2014, Andreas Böhler co-founded the R'n'B Medical Software Consulting GmbH headquartered in Linz/Austria. The company focuses on quality management consulting and also offers a fully electronic quality management system. Given the strong medical and technical backgrounds of the founders, they are also specialised in clinical evaluations.
Textul de pe ultima copertă
In this thesis, a tracking system was developed by modifying an add-on collimator, the Siemens Moduleaf, for realtime applications in radiotherapy. As the add-on collimator works almost completely autonomously of the linear accelerator (LinAc), no modifications to the latter were necessary. The adaptations to the Moduleaf were mainly software-based. In order to reduce the complexity of the system, outdated electronic parts were replaced with newer components where practical.
Verification was performed by measuring the latency of the system as well as the impact on applied dose to a predefined target volume, moving in the leaf's travel direction. Latency measurements in software were accomplished by comparing the target and current positions of the leaves. For dose measurements, a Gafchromic EBT2 film was placed beneath the target 4D phantom, in between solid water plates, and moved alongside with it.
Based on the results, a tracking-capable add-on collimator seems to be a useful tool for reducing the margins for the treatment of small, slow-moving targets.
Radiotherapy is one of the most important methods used for the treatment of cancer. Irradiating a moving target is also one of the most challenging tasks to accomplish in modern radiotherapy.
Verification was performed by measuring the latency of the system as well as the impact on applied dose to a predefined target volume, moving in the leaf's travel direction. Latency measurements in software were accomplished by comparing the target and current positions of the leaves. For dose measurements, a Gafchromic EBT2 film was placed beneath the target 4D phantom, in between solid water plates, and moved alongside with it.
Based on the results, a tracking-capable add-on collimator seems to be a useful tool for reducing the margins for the treatment of small, slow-moving targets.
Radiotherapy is one of the most important methods used for the treatment of cancer. Irradiating a moving target is also one of the most challenging tasks to accomplish in modern radiotherapy.
Caracteristici
Includes supplementary material: sn.pub/extras