Cantitate/Preț
Produs

Conversion of Coal-Fired Power Plants to Cogeneration and Combined-Cycle: Thermal and Economic Effectiveness

Autor Ryszard Bartnik, Zbigniew Buryn
en Limba Engleză Hardback – 28 iul 2011
Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle presents the methodology, calculation procedures and tools used to support enterprise planning for adapting power stations to cogeneration and combined-cycle forms.
The authors analyze the optimum selection of the structure of heat exchangers in a 370 MW power block, the structure of heat recovery steam generators and gas turbines. Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle also addresses the problems of converting existing power plants to dual-fuel gas-steam combined-cycle technologies coupled with parallel systems.
Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle is an informative monograph written for researchers, postgraduate students and policy makers in power engineering.
Citește tot Restrânge

Toate formatele și edițiile

Toate formatele și edițiile Preț Express
Paperback (1) 54957 lei  39-44 zile
  SPRINGER LONDON – 31 aug 2014 54957 lei  39-44 zile
Hardback (1) 64006 lei  6-8 săpt.
  SPRINGER LONDON – 28 iul 2011 64006 lei  6-8 săpt.

Preț: 64006 lei

Preț vechi: 75301 lei
-15% Nou

Puncte Express: 960

Preț estimativ în valută:
12251 12741$ 10266£

Carte tipărită la comandă

Livrare economică 13-27 martie

Preluare comenzi: 021 569.72.76

Specificații

ISBN-13: 9780857298553
ISBN-10: 0857298550
Pagini: 151
Ilustrații: X, 154 p.
Dimensiuni: 155 x 235 x 11 mm
Greutate: 0.41 kg
Ediția:2011
Editura: SPRINGER LONDON
Colecția Springer
Locul publicării:London, United Kingdom

Public țintă

Research

Cuprins

1. Introduction.- 2. Selection of Optimal Heating Structures for Modernization of Coal-Fired Power Stations to Cogeneration.- 3. Mathematical Model of a Power Unit with Rated Capacity of 370 MW After Its Modernization to Cogeneration and Combined-Cycle.- 4. Algorithm for the Calculation of an Optimum Structure of Heat Exchangers for the Modernization of a 370 MW Power Unit to Combined Heat and Power Cycle.- 5. Testing Calculations of the Mathematical Model of a Power Unit.- 6. Thermodynamic Analysis of a Combined Heat and Power Unit Using Extractions A2, A3 and Crossoverpipe IP-LP for Heater Supply.- 7. Economic Efficiency of a Power Unit Adapted to Cogeneration.- 8. Technical and Economical Effectiveness of Modernization 370 MW Power Unit Repowered by Gas Turbine with Their Modernization to Cogeneration.- 9. Technical and Economical Effectiveness of 370 MW Power Unit Repowered by Gas Turbine in Parallel System.- 10. Summary and Final Conclusions.

Textul de pe ultima copertă

Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle presents the methodology, calculation procedures and tools used to support enterprise planning for adapting power stations to cogeneration and combined-cycle forms.
The authors analyze the optimum selection of the structure of heat exchangers in a 370 MW power block, the structure of heat recovery steam generators and gas turbines. Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle also addresses the problems of converting existing power plants to dual-fuel gas-steam combined-cycle technologies coupled with parallel systems.
Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle is an informative monograph written for researchers, postgraduate students and policy makers in power engineering.

Caracteristici

Shows the problems affecting conversion of existing power plants to dual-fuel gas-steam combined-cycle technologies coupled in parallel systems Contains a high proportion of figures to text, to aid the reader's understanding of the subject matter Gives an analysis of the optimum selection of the structure of heat exchangers in a 370 MW power block, and optimum selection of gas turbines and structure of heat recovery steam generators