Autor Ryszard Bartnik, Zbigniew Burynen Limba Engleză Hardback – 28 iul 2011
The authors analyze the optimum selection of the structure of heat exchangers in a 370 MW power block, the structure of heat recovery steam generators and gas turbines. Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle also addresses the problems of converting existing power plants to dual-fuel gas-steam combined-cycle technologies coupled with parallel systems.
Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle is an informative monograph written for researchers, postgraduate students and policy makers in power engineering.
Toate formatele și edițiile | Preț | Express |
---|---|---|
Paperback (1) | 549.57 lei 38-44 zile | |
SPRINGER LONDON – 31 aug 2014 | 549.57 lei 38-44 zile | |
Hardback (1) | 627.11 lei 43-57 zile | |
SPRINGER LONDON – 28 iul 2011 | 627.11 lei 43-57 zile |
Preț: 627.11 lei
Preț vechi: 737.78 lei
-15% Nou
Puncte Express: 941
Preț estimativ în valută:
120.02€ • 124.67$ • 99.69£
120.02€ • 124.67$ • 99.69£
Carte tipărită la comandă
Livrare economică 03-17 februarie 25
Preluare comenzi: 021 569.72.76
Specificații
ISBN-13: 9780857298553
ISBN-10: 0857298550
Pagini: 151
Ilustrații: X, 154 p.
Dimensiuni: 155 x 235 x 11 mm
Greutate: 0.41 kg
Ediția:2011
Editura: SPRINGER LONDON
Colecția Springer
Locul publicării:London, United Kingdom
ISBN-10: 0857298550
Pagini: 151
Ilustrații: X, 154 p.
Dimensiuni: 155 x 235 x 11 mm
Greutate: 0.41 kg
Ediția:2011
Editura: SPRINGER LONDON
Colecția Springer
Locul publicării:London, United Kingdom
Public țintă
ResearchCuprins
1. Introduction.- 2. Selection of Optimal Heating Structures for Modernization of Coal-Fired Power Stations to Cogeneration.- 3. Mathematical Model of a Power Unit with Rated Capacity of 370 MW After Its Modernization to Cogeneration and Combined-Cycle.- 4. Algorithm for the Calculation of an Optimum Structure of Heat Exchangers for the Modernization of a 370 MW Power Unit to Combined Heat and Power Cycle.- 5. Testing Calculations of the Mathematical Model of a Power Unit.- 6. Thermodynamic Analysis of a Combined Heat and Power Unit Using Extractions A2, A3 and Crossoverpipe IP-LP for Heater Supply.- 7. Economic Efficiency of a Power Unit Adapted to Cogeneration.- 8. Technical and Economical Effectiveness of Modernization 370 MW Power Unit Repowered by Gas Turbine with Their Modernization to Cogeneration.- 9. Technical and Economical Effectiveness of 370 MW Power Unit Repowered by Gas Turbine in Parallel System.- 10. Summary and Final Conclusions.
Textul de pe ultima copertă
Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle presents the methodology, calculation procedures and tools used to support enterprise planning for adapting power stations to cogeneration and combined-cycle forms.
The authors analyze the optimum selection of the structure of heat exchangers in a 370 MW power block, the structure of heat recovery steam generators and gas turbines. Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle also addresses the problems of converting existing power plants to dual-fuel gas-steam combined-cycle technologies coupled with parallel systems.
Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle is an informative monograph written for researchers, postgraduate students and policy makers in power engineering.
The authors analyze the optimum selection of the structure of heat exchangers in a 370 MW power block, the structure of heat recovery steam generators and gas turbines. Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle also addresses the problems of converting existing power plants to dual-fuel gas-steam combined-cycle technologies coupled with parallel systems.
Conversion of Coal-Fired Power Plant to Cogeneration and Combined-Cycle is an informative monograph written for researchers, postgraduate students and policy makers in power engineering.
Caracteristici
Shows the problems affecting conversion of existing power plants to dual-fuel gas-steam combined-cycle technologies coupled in parallel systems Contains a high proportion of figures to text, to aid the reader's understanding of the subject matter Gives an analysis of the optimum selection of the structure of heat exchangers in a 370 MW power block, and optimum selection of gas turbines and structure of heat recovery steam generators