MDCT Protocols: Whole Body and Emergencies
Editat de Andrea Laghien Limba Engleză Paperback – 8 dec 2011
The examination quality and the consequent diagnostic accuracy of MDCT are the results of an optimized study technique, which nonetheless needs to be adapted to the particular clinical situation of the patient, while bearing in mind the radiation exposure. Another fundamental parameter in the optimization of MDCT is the protocol for the intravenous injection of iodinated contrast material; in these studies, multiple variables, some modifiable by the operator and others patient-dependent, must be considered based on the aims of maximizing arterial and venous enhancements whilst minimizing the dose of iodine injected, saving money, and increasing patient safety.
Through the presentation of cases addressing different anatomical regions and various clinical indications, including emergency and neuro-imaging, this volume seeks to provide the general radiologist and trainee specialist with a guide to the main study protocols to be implemented in order to optimize examination quality and, consequently, facilitate the diagnostic process.
Preț: 716.84 lei
Preț vechi: 754.56 lei
-5% Nou
Puncte Express: 1075
Preț estimativ în valută:
137.20€ • 142.70$ • 114.98£
137.20€ • 142.70$ • 114.98£
Carte disponibilă
Livrare economică 20 februarie-06 martie
Preluare comenzi: 021 569.72.76
Specificații
ISBN-13: 9788847024021
ISBN-10: 8847024021
Pagini: 253
Ilustrații: 253 p.
Greutate: 0.45 kg
Ediția:2012
Editura: Springer
Colecția Springer
Locul publicării:Milano, Italy
ISBN-10: 8847024021
Pagini: 253
Ilustrații: 253 p.
Greutate: 0.45 kg
Ediția:2012
Editura: Springer
Colecția Springer
Locul publicării:Milano, Italy
Public țintă
Professional/practitionerCuprins
Technical Basis.- Introduction.- The Technology.- Contrast-Medium Administration.- Special Examinations.- Essential References.- Clinical Cases.- Neuro.-Thorax.- Abdomen.-Heart.- Vascular.- Emergency.
Textul de pe ultima copertă
Multidetector-row computed tomography (MDCT) has become a fundamental imaging technique for the study of many anatomical districts in different clinical situations, as it provides a fast, reliable, and accurate simultaneous evaluation of different organs, including parenchyma, hollow viscera, vessels, and bony structures. It has also equipped the radiologist with the ability to explore areas that in the last decade were largely ignored by CT, especially the coronary arteries and the colon, and to limit invasive diagnostic tests (e.g., catheter angiography) to those cases in which interventional procedures are required.
The examination quality and the consequent diagnostic accuracy of MDCT are the results of an optimized study technique, which nonetheless needs to be adapted to the particular clinical situation of the patient, while bearing in mind the radiation exposure. Another fundamental parameter in the optimization of MDCT is the protocol for the intravenous injection of iodinated contrast material; in these studies, multiple variables, some modifiable by the operator and others patient-dependent, must be considered based on the aims of maximizing arterial and venous enhancements whilst minimizing the dose of iodine injected, saving money, and increasing patient safety.
Through the presentation of cases addressing different anatomical regions and various clinical indications, including emergency and neuro-imaging, this volume seeks to provide the general radiologist and trainee specialist with a guide to the main study protocols to be implemented in order to optimize examination quality and, consequently, facilitate the diagnostic process.
The examination quality and the consequent diagnostic accuracy of MDCT are the results of an optimized study technique, which nonetheless needs to be adapted to the particular clinical situation of the patient, while bearing in mind the radiation exposure. Another fundamental parameter in the optimization of MDCT is the protocol for the intravenous injection of iodinated contrast material; in these studies, multiple variables, some modifiable by the operator and others patient-dependent, must be considered based on the aims of maximizing arterial and venous enhancements whilst minimizing the dose of iodine injected, saving money, and increasing patient safety.
Through the presentation of cases addressing different anatomical regions and various clinical indications, including emergency and neuro-imaging, this volume seeks to provide the general radiologist and trainee specialist with a guide to the main study protocols to be implemented in order to optimize examination quality and, consequently, facilitate the diagnostic process.
Caracteristici
Practical handbook with easy-to-read and simple proposals of MDCT protocols Many examples from routine clinical practice No other similar work in the literature