Cantitate/Preț
Produs

Physical and Statistical Models for Steam Generator Clogging Diagnosis: SpringerBriefs in Applied Sciences and Technology

Autor Sylvain Girard
en Limba Engleză Paperback – 7 aug 2014
Clogging of steam generators in nuclear power plants is a highly sensitive issue in terms of performance and safety and this book proposes a completely novel methodology for diagnosing this phenomenon. It demonstrates real-life industrial applications of this approach to French steam generators and applies the approach to operational data gathered from French nuclear power plants. The book presents a detailed review of in situ diagnosis techniques and assesses existing methodologies for clogging diagnosis, whilst examining their limitations. It also addresses numerical modelling of the dynamic behaviour of steam generators and provides a thorough analysis of statistical methods for sensitivity analysis and dimension reduction. Steam generators are heat exchangers found in nuclear power plants and over time they become increasingly clogged by iron oxides. This clogging then hampers the flow inside steam generators and compromises their mechanical integrity, which hinders performance and safety. This book is intended for nuclear safety specialists, nuclear performance engineers and researchers and postgraduate students working on heat exchanger modeling and computational engineering.
Citește tot Restrânge

Din seria SpringerBriefs in Applied Sciences and Technology

Preț: 36320 lei

Nou

Puncte Express: 545

Preț estimativ în valută:
6951 7333$ 5793£

Carte tipărită la comandă

Livrare economică 02-16 ianuarie 25

Preluare comenzi: 021 569.72.76

Specificații

ISBN-13: 9783319093208
ISBN-10: 3319093207
Pagini: 106
Ilustrații: IX, 97 p. 76 illus., 42 illus. in color.
Dimensiuni: 155 x 235 x 12 mm
Greutate: 0.16 kg
Ediția:2014
Editura: Springer International Publishing
Colecția Springer
Seria SpringerBriefs in Applied Sciences and Technology

Locul publicării:Cham, Switzerland

Public țintă

Professional/practitioner

Cuprins

1 Introduction.- 2 Clogging of recirculating nuclear steam generators.- 3 State of the art of clogging diagnosis.- 4 Steam generator physical model.- 5 Sensitivity analysis.- 6 Sliced inverse regression.- 7 Statistical analysis of the physical model.- 8 New diagnosis method.- 9 Synthesis and usage recommendation.- Appendix A Characteristics of the type 51B steam generator.

Notă biografică

Dr. Sylvain Girard current research interests are uncertainty analysis and dimension reduction applied to models of complex industrial and environmental systems. Since 2013, he has been working on the characterisation of uncertainties of radionuclides atmospheric dispersion models for the Institut de radioprotection et de sûreté nucléaire (IRSN).
Dr. Girard investigated nuclear steam generators clogging during his PhD at Électricité de France (EDF, the french electricity company and a leader in nuclear engineering worldwide) under the direction of Pr. Hans Wackernagel at École des Mines Paris Tech. He elaborated a new methodology for clogging diagnosis coupling physical and statistical modelling.

Caracteristici

Proposes a novel methodology for diagnosing clogging of steam generators in nuclear power plants Demonstrates real-life industrial applications of this methodology to French steam generators Presents a detailed review of existing methodologies for clogging diagnosis and examines their limitations Includes supplementary material: sn.pub/extras