Cantitate/Preț
Produs

Sustainable Retrofitting of Commercial Buildings: Warm Climates

Autor Richard Hyde, Nathan Groenhout, Francis Barram, Ken Yeang
en Limba Engleză Paperback – 30 iun 2020
Despite recent improvements in energy efficiency being made in new build, it is important that the existing commercial building sector also take action to meet emission reduction targets. The objectives and challenges of such action will reduce the risk of the sector becoming obsolete due to high energy use and poor environmental performance.


This book presents a theory-based, practice-support methodology to deal with sustainable retrofitting opportunities for existing commercial buildings in warm climates using bioclimatic design as the basis. The book has four main parts, focusing on eco-design and renovation, bioclimatic retrofitting, technological and behavioural change and case studies of retrofitting exemplars. In the first part, the context of climate change effects on design and renovation at the city scale is discussed. The second part looks at bioclimatic retrofitting as a 'design guide' for existing buildings, highlighting the significance of architectural design and engineering systems for energy performance. The technological and behavioural contexts of the existing building sector – policies, modelling, monitoring and trend analysis in respect to energy and environmental performance – are covered in part three. The final part gives some case studies showing the effectiveness of strategies suggested for effective environmental performance. This book is a must-have guide for all involved in the design and engineering of retrofitting projects in warm climates.
Citește tot Restrânge

Toate formatele și edițiile

Toate formatele și edițiile Preț Express
Paperback (1) 31065 lei  43-57 zile
  CRC Press – 30 iun 2020 31065 lei  43-57 zile
Hardback (1) 84868 lei  43-57 zile
  CRC Press – 20 sep 2012 84868 lei  43-57 zile

Preț: 31065 lei

Preț vechi: 35662 lei
-13% Nou

Puncte Express: 466

Preț estimativ în valută:
5946 6197$ 4950£

Carte tipărită la comandă

Livrare economică 06-20 ianuarie 25

Preluare comenzi: 021 569.72.76

Specificații

ISBN-13: 9780367576677
ISBN-10: 0367576678
Pagini: 512
Dimensiuni: 156 x 234 mm
Greutate: 0.45 kg
Ediția:1
Editura: CRC Press
Colecția Routledge
Locul publicării:Boca Raton, United States

Public țintă

Professional Practice & Development

Cuprins

Part 1: Eco Design and Renovation  1.1. Introduction  1.2. Strategies for Design of Our Green Built Environment  1.3. Eco Design for Retrofitting  1.4. Summary  Part 2: Bioclimatic Retrofitting  2.1. Introduction  2.2. Design Solution Sets For Bioclimatic Retrofit  2.3. An Evidenced-Base Design (Ebd) Approach For Selecting Retrofitting Strategies  2.4. Performance Improvements Of Retrofitting Design Solution Sets  2.5. The Economic Case for Retrofitting Using Bioclimatic Principles (Francis Barram)  2.6. Summary  Part 3: Technological and Behaviour Change for Performance Improvements  3.1 Introduction  3.2. Evaluation Typologies of Commercial Architecture For Retrofitting  3.3. Retrofitting Comfort And Indoor Environmental Quality  3.4. Reviewing Benchmarking Systems For Retrofitting  3.5. Energy Performance Rating Systems  3.6. Performance Modelling Tools  3.7. Monitoring Building Performance  3.8. A Diagnostic Toolkit for Multi-Dimensional Testing Of Built Internal Environments  3.9. Reducing Embodied Energy Through Retrofit  3.10. A Checklist For Reducing Peak Energy Loads In Buildings: A Staged Approach  3.11. Penalty-Reward-Pinch (PRP) Design In Commercial Building Sustainability  3.12. Economic Drivers For Renovation  3.13. A Bioclimatic Design Approach For Retrofitting Commercial Office Buildings  3.14. Summary  Part 4: Retrofitting Exemplars  4.1. Introduction  4.2. PMM Building; Passive Systems Improvement 4.3. 55 St Andrews Place; Turning a Sparrow into a Peacock  4.4. Bioclimatic Retrofitting Of University Buildings  4.5. 503 Collins Street  4.6. Solar Thermal Retrofit  4.7. Benefits And Impacts Of Adjusting Cooling Set-Points In Brisbane  4.8. Low Energy High-Rise  4.9. Refurbishment for Carbon Reduction and Occupant Comfort – Insights from the Post Occupancy Evaluation of Three Office Buildings  4.10. The Deakin University Waterfront Campus – Callista Offices A Case Study

Notă biografică



Richard Hyde is Professor of Architectural Science at the University of Sydney, Australia. He is a registered architect engaged in the field of sustainable architectural design and research for buildings. He is currently Associate Dean Research, Editor-in-Chief of Architectural Science Review and Coordinator of the Sustainable Design Program, Faculty of Architecture Design and Planning, the University of Sydney.

Nathan Groenhout is a consultant providing ecologically sustainable design, thermal and energy modelling, and research and development in building innovation. He is currently Adjunct Associate Professor in the Faculty of Architecture Design and Planning at the University of Sydney, Australia. In January 2002, he was a Visiting Research Scholar at the Institute of Fluid Science, Tohoku University, Japan whilst completing his PhD in numerical and experimental investigations of advanced solar water heaters.

Francis Barram is an author and energy analyst with extensive experience in the design of sustainable building services and industrial processes. He is a member of the Australian Standards Energy Audit Standard Committee and founder and Managing Director of Ensight, an award winning national consultancy.


Ken Yeang is an architect, planner and ecologist. He is the Chairman and Design Director of Llewelyn Davies Yeang (UK) and principal of T. R. Hamzah & Yeang (Malaysia). He is the Distinguished Plym Professor at the University of Illinois, USA, and has received international awards for his architecture and masterplans.


Descriere

Presents a methodology for retrofitting existing commercial buildings in warm climates, using bioclimatic design