Cantitate/Preț
Produs

Water Supply Byelaws Guide

Autor S.F. White, G.D. Mays
en Limba Engleză Paperback – mai 1990
In February 1985 a Byelaws Guidance Panel{1) was formed by the United Kingdom Water Fittings Byelaws Scheme(2) to produce a Guide to Byelaws the aim being that it should: (a) assist water inspectors, manufacturers, architects, consultants, merchants, installers and consumers to understand byelaws based on the Model; (b) bring about uniformity of approach to byelaw enforcement throughout the UK; (c) be suitable for use as a training document; {d) be subject to continual review by the Panel to ensure its compliance with the latest requirements; (e) comply with byelaw guidance issued by the Department of the Environment; and (f) be based wherever possible on British Standards. 3. This Guide is intended to be applicable throughout the United Kingdom and includes a copy of each byelaw.
Citește tot Restrânge

Toate formatele și edițiile

Toate formatele și edițiile Preț Express
Paperback (1) 44935 lei  6-8 săpt.
  Taylor & Francis – mai 1990 44935 lei  6-8 săpt.
Hardback (1) 87420 lei  6-8 săpt.
  Taylor & Francis – 31 mar 2017 87420 lei  6-8 săpt.

Preț: 44935 lei

Preț vechi: 52864 lei
-15% Nou

Puncte Express: 674

Preț estimativ în valută:
8602 8942$ 7132£

Carte tipărită la comandă

Livrare economică 06-20 februarie 25

Preluare comenzi: 021 569.72.76

Specificații

ISBN-13: 9780139503955
ISBN-10: 0139503951
Pagini: 264
Dimensiuni: 138 x 216 x 27 mm
Greutate: 0.39 kg
Ediția:Revizuită
Editura: Taylor & Francis
Colecția Routledge
Locul publicării:Oxford, United Kingdom

Cuprins

FOREWORD v NOTES ON THE USE OF THE GUIDE vii INDEX TO BYELAWS ix PART I GENERAL PROVISIONS PART II PREVENTION OF CONTAMINATION OF 17 WATER FROM CONTACT WITH UNSUITABLE MATERIALS OR SUBSTANCES PART Ill PREVENTION OF CONTAMINATION OF 27 WATER BY BACKSIPHONAGE, BACKFLOW OR CROSS-CONNECTION PART IV PREVENTION OF WASTE, OR 91 CONTAMINATION OF STORED WATER PART V PREVENTION OF WASTE OF WATER 117 FROM DAMAGE TO WATER FITTINGS FROM CAUSES OTHER THAN CORROSION PART VI PREVENTION OF WASTE FROM OR 127 CONTAMINATION BY UNSUITABLE OR IMPROPERLY INSTALLED WATER FITTINGS PART VII STOPVALVES, ETC. 159 PART VIII WATERCLOSETS AND URINALS 175 PART IX PREVENTION OF WASTE, MISUSE AND 189 CONTAMINATION OF WATER FROM DRAW-OFF TAPS, BATHS, BASINS, SINKS AND OTHER FITTINGS PART X PREVENTION OF WASTE OR 197 CONTAMINATION OF WATER FROM ANY HOT WATER SYSTEM PART XI TAPS FOR DRAWING DRINKING WATER 209 PART XII NOTICES TO UNDERTAKERS 213 PART XIII PENALTIES 217 PART XIV REVOCATION 219 APPENDIX A - CONSTITUTION OF PANEL PRODUCING 223 GUIDE APPENDIX B - METRIC CONVERSION TABLES 224 APPENDIX C - LIST OF BRITISH STANDARDS CITED 225 IN GUIDE GUIDE REFERENCES