Cantitate/Preț
Produs

Omnidirectional Inductive Powering for Biomedical Implants: Analog Circuits and Signal Processing

Autor Bert Lenaerts, Robert Puers
en Limba Engleză Hardback – 24 oct 2008
Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Special attention is paid to the interaction of the inductive power link with the patient’s body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter.
Citește tot Restrânge

Toate formatele și edițiile

Toate formatele și edițiile Preț Express
Paperback (1) 90613 lei  6-8 săpt.
  SPRINGER NETHERLANDS – 28 oct 2010 90613 lei  6-8 săpt.
Hardback (1) 91191 lei  6-8 săpt.
  SPRINGER NETHERLANDS – 24 oct 2008 91191 lei  6-8 săpt.

Din seria Analog Circuits and Signal Processing

Preț: 91191 lei

Preț vechi: 111210 lei
-18% Nou

Puncte Express: 1368

Preț estimativ în valută:
17453 18412$ 14544£

Carte tipărită la comandă

Livrare economică 02-16 ianuarie 25

Preluare comenzi: 021 569.72.76

Specificații

ISBN-13: 9781402090745
ISBN-10: 1402090749
Pagini: 240
Ilustrații: XVI, 222 p.
Dimensiuni: 155 x 235 x 19 mm
Greutate: 0.51 kg
Ediția:2009
Editura: SPRINGER NETHERLANDS
Colecția Springer
Seria Analog Circuits and Signal Processing

Locul publicării:Dordrecht, Netherlands

Public țintă

Research

Cuprins

Magnetic Induction.- Inductive Link Design.- Power Converters and Voltage Regulators.- Omnidirectional Coupling.- Biological Tissue Interaction.- An Inductive Power Link for a Capsule Endoscope.- A Class E Driver for Deformable Coils.- Conclusions.

Textul de pe ultima copertă

In the year 2000, a capsule endoscope was introduced on the market for diagnosis of small bowel diseases. This pill, about one centimeter in diameter, takes images of the gastric track and transmits them wirelessly to the outside world. Since the capsule is battery powered, the limited energy budget restricts both the amount and the quality of images that can be shot. To resolve this limitation, Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Useful rectifier and inverter topologies are presented, including a class E driver that copes with coil deformations. Special attention is paid to the interaction of the inductive power link with the patient’s body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter.

Caracteristici

Handbook on inductive link design, in-depth theoretical analysis plus implementation Only existing analysis on 3D (omnidirectional) inductive powering systems Implementation of an inductive link for a capsule endoscope Interface study between humans and magnetic fields Includes supplementary material: sn.pub/extras